Vitara JX (4Dr) 4WD L4-2.0L (2000)
Condenser HVAC: Service and Repair
CONDENSER
REMOVAL
1. Disconnect negative (-) cable at battery.
2. Recover refrigerant by using recovery and recycling equipment. Be sure to follow the instruction manual for the equipment. The amount of
compressor oil removed must be measured and the same amount added to the system.
3. Remove front bumper assembly and lower stay.
G16 And J20 Engine
H25 Engine
4. Disconnect compressor delivery hose from condenser inlet fittings.
NOTE: As soon as above hose and pipe are disconnected, cap opened fittings so that moisture and dust do not enter condenser.