suzuki Workshop Repair Guides

Suzuki Workshop Service and Repair Manuals

Symptom Related Diagnostic Procedures|Page 2589 > < Symptom Related Diagnostic Procedures
Page 2
background image

1. Run engine from idling up to 2,000 rpm and read meters.

NOTE:  Turn off switches of all accessories (wiper, heater etc.).

Standard current: 10 A maximum

Standard voltage: 
14.4 - 15.0 V (at 20 °C, 68 °F) 60 A and 70 A  types
14.1 - 15.2 V (at 20 °C, 68 °F) 85 A type

NOTE:  Consideration should be taken that voltage will differ somewhat with regulator case temperature as shown in the figure.

Higher Voltage
If voltage is higher than standard value, check ground of brushes.
If brushes are not grounded, replace IC regulator.

Lower Voltage
[60 A and 70 A types]
If voltage is below or in standard value, increase engine speed up to 2000 - 2500 rpm soon after starting engine, and read maximum value on
ammeter immediately.
If current is less than 42 A (60 A type) or 49 A (70 A type), repair or replace generator.

[85 A type]
If voltage is lower than standard value, proceed to following check.

2. Ground F terminal and start engine, then measure voltage at B terminal as shown in figure.

-

Voltage is higher than standard value
It is considered that generator itself is good but IC regulator has been damaged, replace IC regulator.

-

Voltage is lower than standard value

Symptom Related Diagnostic Procedures|Page 2589 > < Symptom Related Diagnostic Procedures