5. Turn power supply switch OFF.

CAUTION:  Do not feed current 1.0 A or more, or pressure control solenoid will be burned out.

[Not using regulated DC power supply]

6. Connect pressure control solenoid valve (1) to battery (4) setting 21 W bulb (2) in between as shown in the figure.
7. Check that valve (3) moves in arrow "A" direction.
8. Disconnect pressure control solenoid valve (1) from battery (4) and check that valve (3) moves in arrow "B" direction as shown in the figure.

CAUTION:  Set 21 W bulb in between, or pressure control solenoid valve will be burned out.