5. Once the locking tabs are unlocked, slide the inner connector out of the rear of the connector housing.
6. Use the J 38125-12A (GM P/N 12094429) tool to release the terminals by pressing on the tang. See the release tool cross reference in the

Reference Guide of the J-38125 to ensure that the correct release tool is used.

7. While holding the removal tool in place, gently pull the wire out of the back of the connector.

Always remember never use force when pulling a terminal out of a connector.

Repair Procedure

Use the appropriate terminal and follow the instructions in the J-38125.
Location of the terminal in the repair tray and the proper crimp tool can be found in the appropriate connector end view.

Tyco/AMP Connectors (Sensor)

Tyco/AMP Connectors (Sensor)

Special Tool
J-38125 Terminal Repair Kit

Terminal Removal Procedure