1. Disconnect the connector from the component by pressing down on the connector position assurance (CPA).
2. Use a small flat-bladed tool to release the terminal position assurance (TPA) by inserting the tool in the small recess on the side of the connector

and pushing up until the TPA releases from the connector body. The TPA should raise just slightly. Do not try to remove the TPA.

NOTE:  The TPA on this connector cannot be removed unless the terminals are removed first. The TPA will come out of the connector body, but
only slightly. When the TPA is slightly raised the terminals can be removed. Using excessive force to remove the TPA with the terminals still in
the connector will damage the connector.

3. Repeat the process for the other side of the connector.