suzuki Workshop Repair Guides

Suzuki Workshop Service and Repair Manuals

Diagram Information and Instructions|Page 18010 > < Diagram Information and Instructions|Page 18008
Page 122
background image

^

When adding a length of wire to the existing harness, use the same size wire as the original wire.

^

Perform one of the following items in order to find the correct wire size:
-

Find the wire on the schematic and convert the metric size to the equivalent American wire gage (AWG) size.

-

Use an AWG wire gage.

-

If you are unsure of the wire size, begin with the largest opening in the wire stripper and work down until achieving a clean strip of the
insulation.

^

Strip approximately 7.5 mm (0.313 in) of insulation from each wire to be spliced.

^

Do not nick or cut any of the strands. Inspect the stripped wire for nicks or cut strands.

^

If the wire is damaged, repeat this procedure after removing the damaged section.

4. Select the proper DuraSeal splice sleeve according to the wire size. Refer to the table at the beginning of the repair procedure for the color coding

of the DuraSeal splice sleeves and the crimp tool nests.

Diagram Information and Instructions|Page 18010 > < Diagram Information and Instructions|Page 18008