Blower Motor Relay: Testing and Inspection
Blower Motor Relay

Blower Motor Relay Inspection

1. Connect battery positive (+) terminal to terminal (1) of relay.
2. Connect battery negative (-) terminal to terminal (2) of relay.
3. Check continuity between terminal (3) and (4).

If there is no continuity, replace relay.