Page 1
background image

Refrigerant Pressure Sensor / Switch: Testing and Inspection

Dual (Refrigerant) Pressure Switch Inspection

1. Check dual pressure switch (1) on liquid pipe for continuity at normal temperature (approx. 25 °C, 77 °F) when A/C system has a proper charge of

refrigerant and when A/C system (compressor) is under operation. In each of these cases, switches should show proper continuity.

2. Using a manifold gauge set, check switch for operation specified pressure as shown, refer to "A/C System Performance Inspection:".

Dual pressure switch specification 
Switch ON: above "C" and below "D" 
Switch OFF: below "A" or above "B" 
"A": Approx. 200 kPa (2.0 kg/sq.cm)
"B": Approx. 3200 kPa (32 kg/sq.cm)
"C": Approx. 23 kPa (2.3 kg/sq.cm) 
"D": Approx. 2800 kPa (28 kg/sq.cm)

Tightening torque
Dual pressure switch: 10 N.m (1.0 kg-m, 7.5 lb-ft)