suzuki Workshop Repair Guides

Suzuki Workshop Service and Repair Manuals

Rotor, Alternator > < Alternator Brush|Testing and Inspection
Page 1
background image

Rectifier Diode / Bridge: Testing and Inspection

Rectifier

Positive Rectifier

1. Using an ohmmeter, connect one tester probe to the "B" terminal (1) and the other to each rectifier terminal (2).
2. Reverse the polarity of the tester probes and repeat Step 1).
3. Check that one shows continuity and the other shows no continuity. If there is continuity, replace the rectifier.

Negative Rectifier

1. Using an ohmmeter, connect one tester probe to each negative terminal (1) and the other to each rectifier terminal (2).
2. Reverse the polarity of the tester probes and repeat Step 1).
3. Check that one shows continuity and the other shows no continuity. If there is continuity, replace the rectifier.

Rotor, Alternator > < Alternator Brush|Testing and Inspection