XL-7 Touring 4WD V6-2.7L (2002)
Power Door Lock Actuator: Testing and Inspection
Operation Check
Power Door Lock Actuator Circuit
1. Disconnect negative (-) cable at battery.
2. Disconnect coupler of power door lock and keyless entry controller.
3. Use a 12 V battery to connect its (+) terminal to terminal "G36-1", and its (-) terminal to terminal "G36-2" and "G36-3". Check all power doors
are locked.
If check result is satisfactory, this circuit is OK.