XL-7 Touring 4WD V6-2.7L (2002)
Blower Motor: Testing and Inspection
Heater Blower Motor
Heater Blower Motor Inspection
-
Check continuity between terminal to terminal as shown in figure. If check results are continuity, proceed to next operation check. If not, replace.
-
Connect battery to blower motor as shown, then check that the blower motor operates smoothly.
Reference current for blower motor
18 - 24 A at 12 V