suzuki Workshop Repair Guides

Suzuki Workshop Service and Repair Manuals

Refueling Vapor Recovery System > < EVAP Canister Vent Valve and Its Circuit Inspection|Page 1706
Page 1
background image

Leak Detection Valve: Testing and Inspection

EVAP Leakage Inspection

1. Disconnect purge hose from EVAP canister purge valve.
2. Plug vent valve hose end.

3. Apply 3.5 kPa (14.0 in.Aq, 26.0 mmHg) to purge hose and seal it. After 15 second, check to make sure that pressure is higher than 3.3 kPa (13.6

in.Aq, 24.5 mmHg).

If check result is not satisfactory, locate pressure leaking point by using soap water or leak detector.

If no pressure leakage exists in vapor purge line, fuel filler cap, filler neck and etc., remove fuel tank from vehicle and check for leakage from
installation face of parts installed on fuel tank and hose joint.

Refueling Vapor Recovery System > < EVAP Canister Vent Valve and Its Circuit Inspection|Page 1706