toyota Workshop Repair Guides

Toyota Workshop Service and Repair Manuals

Expansion Valve > < A/C - Evaporator Odor|Page 3247
Page 2
background image

Fig. 13  Exploded View Of Cooling Unit.

1.

Disconnect battery ground cable and discharge system refrigerant.

2.

Disconnect refrigerant lines at cooling unit Fig. 12, capping all openings.

3.

Remove grommets from inlet and outlet fittings.

4.

Remove glove compartment and glove compartment stay.

5.

Disconnect A/C switch connector and the connector connected to A/C harness.

6.

Remove four attaching screws and bolt, then the cooling unit.

7.

Remove four clamps and four screws securing case halves Fig. 13, then separate case halves and remove evaporator.

8.

Pull off clamp and remove thermistor.

9.

Remove heat insulator and clamp from outlet tube.

10.

Disconnect liquid line tube from inlet fitting of expansion valve.

11.

Disconnect expansion valve from inlet fitting of evaporator.

12.

Reverse procedure to install, then evacuate the recharge system and check for leaks. If evaporator is replaced, add 1.4-1.7 oz. of new refrigerant
oil to compressor.

Expansion Valve > < A/C - Evaporator Odor|Page 3247