Shift Interlock Solenoid: Testing and Inspection

INSPECTION 

1. INSPECT KEY INTERLOCK SOLENOID

a. Disconnect the solenoid connector.
b. Connect KLS + (4) terminal to the batteries positive (+) terminal, and KLS - (3) terminal to the battery negative (-) terminal, and apply about 

12V between KLS + - KLS - terminals. Check that operation noise can be heard from the solenoid.
If the solenoid does not operate, replace the solenoid.