toyota Workshop Repair Guides

Toyota Workshop Service and Repair Manuals

Diagram Information and Instructions|Page 3969 > < Diagram Information and Instructions|Page 3967
Page 1
background image

Air Flow Meter/Sensor: Testing and Inspection

MASS AIR FLOW METER INSPECTION 

Ohmmeter Connection

Reference Chart

1. Inspect MAF meter resistance.

Using an ohmmeter, measure the resistance between terminals THA and E2.
If the resistance is not as specified, replace the MAF meter.

2. Inspect MAF meter operation. 

(a) Connect the MAF meter connection

Voltmeter Connector

(b) Using a voltmeter, connect the positive (+) tester probe to terminal VG, and negative (-) tester probe to terminal E3.
(c) Blow air into the MAF meter, and check that the voltage fluctuates.

If operation is not as specified, replace the MAF meter.

(d) Disconnect the MAF meter connector.

Diagram Information and Instructions|Page 3969 > < Diagram Information and Instructions|Page 3967