toyota Workshop Repair Guides

Toyota Workshop Service and Repair Manuals

Ignition Cable|Specifications|Page 2851 > < Ignition Cable|Specifications|Page 2849
Page 1
background image

Ignition Cable: Testing and Inspection

High-Tension Cords Inspection 

1. Remove air cleaner cap and MAF meter assembly.
2. Disconnect high-tension cords from spark plugs.

Disconnect the high-tension cords at the rubber boot. DO NOT pull on the cords.

NOTICE:  Pulling on or bending the cords may damage the conductor inside.

3. Disconnect high-tension cords from ignition coils.

(a) Using a screwdriver, lift up the lock claw and disconnect the holder from the ignition coils.
(b) Disconnect the high-tension cord at the grommet. DO NOT pull on the cord.

NOTICE:
-

Pulling on or bending the cords may damage the conductor inside.

-

Do not wipe any of the oil from the grommet after the high-tension cord is disconnected.

4. Inspect high-tension cord resistance.

Using an ohmmeter, measure the resistance.

Maximum resistance: 25 K ohms per cord

If the resistance is greater than the maximum, check the terminals. If necessary, replace the high-tension cord.

Ignition Cable|Specifications|Page 2851 > < Ignition Cable|Specifications|Page 2849