Avalon V6-3.5L (2GR-FE) (2006)
2. Connect a wire to the negative (-) terminal of the transmitter and install the battery.
3. Connect the tester's positive (+) lead to the positive (+) side of the battery (lithium battery) and the tester's negative (-) lead to the wire.
4. Press one of the transmitter switches for approximately 1 second.
5. Press the transmitter switch again to check the voltage.
Standard: 2.2 V or higher
HINT:
-
When the temperature of the battery is low, the inspection cannot be made correctly.
When the outcome of the test is less than 2.2 V, conduct the test again after leaving the battery in a place with a temperature 18°C (64°F)
for more than 30 minutes.
-
Read the voltage immediately after the switch is pressed. When 0.8 seconds have passed after the switch is pressed, the automatic
power-off function starts and resistance applied to the battery will cease. The voltage of the battery will be 2.5 V or more.
-
Press the switch at least 3 times before reading the voltage.
If the battery has just been returned to 18°C (64°F), the voltage may be unusually high for the first or second voltage reading.
6. Disconnect the lead.