Avalon V6-3.5L (2GR-FE) (2006)
Knock Sensor: Testing and Inspection
INSPECT KNOCK CONTROL SENSOR
a. Using an ohmmeter, measure the resistance between the terminals.
Standard: 120 to 280 kOhms at 20 degree C (68 degree F)
If the result is not as specified, replace the sensor.