toyota Workshop Repair Guides

Toyota Workshop Service and Repair Manuals

Activation Prevention Mechanism|Page 7246 > < Activation Prevention Mechanism|Page 7244
Page 4
background image

1. To release the activation prevention mechanism, insert a piece of paper with the same thickness as the male terminal (approximately 0.5 mm

(0.020 in.) between the terminals and the short spring to break the connection.

2. Refer to the illustrations concerning connectors utilizing the activation prevention mechanism and its release method.

CAUTION:  Never release the activation prevention mechanism on the squib connector even when inspecting with the squib disconnected.

NOTE:  
-

Do not release the activation prevention mechanism unless specially directed by the troubleshooting procedure.

-

To prevent the terminal and the short spring from being damaged, always use a piece of paper that is the same thickness as the male
terminal.

Activation Prevention Mechanism|Page 7246 > < Activation Prevention Mechanism|Page 7244