Avalon XL V6-3.0L (1MZ-FE) (1997)
Hose/Line HVAC: Service and Repair
Refrigerant Lines
1. DISCHARGE REFRIGERANT IN REFRIGERATION SYSTEM
2. REPLACE FAULTY TUBE OR HOSE
NOTE: Cap the open fittings immediately to keep moisture or dirt out of the system.
3. TORQUE CONNECTIONS TO SPECIFIED TORQUE
NOTE: Connections should not be torque tighter than the specified torque.
Compressor x Suction hose
Torque: 10 N.m (100 kg.cm, 7 ft.lb)
Compressor x Discharge hose
Torque: 10 N.m (100 kg.cm, 7 ft.lb)
Condenser x Liquid tube
Torque: 10 N.m (100 kg.cm. 7 ft.lb)
Receiver x Liquid tube
Torque: 5.4 N.m (55 kg.cm. 48 in..lb)
Cooling unit x Liquid tube
Torque: 10 N.m (100 kg.cm, 7 ft.lb)
Cooling unit x Suction tube
Torque: 10 N.m (100 kg.cm, 7 ft.lb)
Liquid lines
Torque: 10 N.m (100 kg.cm, 7 ft.lb)
Suction lines
Torque: 10 N.m (100 kg.cm, 7 ft.lb)
4. EVACUATE AIR IN REFRIGERATION SYSTEM AND CHARGE WITH REFRIGERANT
Specified amount:
850 ± 50 g (30.00 ± 1.76 oz.)