toyota Workshop Repair Guides

Toyota Workshop Service and Repair Manuals

Hose/Line HVAC|Locations|Page 1719 > < Hose/Line HVAC|Locations|Page 1717
Page 1
background image

Hose/Line HVAC: Service and Repair

Refrigerant Lines

1. DISCHARGE REFRIGERANT IN REFRIGERATION SYSTEM

2. REPLACE FAULTY TUBE OR HOSE

NOTE:  Cap the open fittings immediately to keep moisture or dirt out of the system.

3. TORQUE CONNECTIONS TO SPECIFIED TORQUE

NOTE:  Connections should not be torque tighter than the specified torque.

Compressor x Suction hose

Torque: 10 N.m (100 kg.cm, 7 ft.lb)

Compressor x Discharge hose

Torque: 10 N.m (100 kg.cm, 7 ft.lb)

Condenser x Liquid tube

Torque: 10 N.m (100 kg.cm. 7 ft.lb)

Receiver x Liquid tube

Torque: 5.4 N.m (55 kg.cm. 48 in..lb)

Cooling unit x Liquid tube

Torque: 10 N.m (100 kg.cm, 7 ft.lb)

Cooling unit x Suction tube

Torque: 10 N.m (100 kg.cm, 7 ft.lb)

Liquid lines

Torque: 10 N.m (100 kg.cm, 7 ft.lb)

Suction lines

Torque: 10 N.m (100 kg.cm, 7 ft.lb)

4. EVACUATE AIR IN REFRIGERATION SYSTEM AND CHARGE WITH REFRIGERANT

Specified amount:

850 ± 50 g (30.00 ± 1.76 oz.)

Hose/Line HVAC|Locations|Page 1719 > < Hose/Line HVAC|Locations|Page 1717