Avalon XL V6-3.0L (1MZ-FE) (1997)
(1) Apply vacuum (2.0 kPa. 15 mmHg. 0.59 in.Hg) to the vapor pressure sensor.
Voltage: 1.3 - 2.1 V
(2) Release the vacuum from the vapor pressure sensor.
Voltage: 2.9 - 3.7 V
(3) Apply pressure (1.5 kPa, 15 gf/sq.cm, 0.22 psi) to the vapor pressure sensor.
Voltage: 4.2 - 4.8 V
(d) Reconnect the vacuum hose to the vapor pressure sensor.