Avalon XL V6-3.0L (1MZ-FE) (1997)
Shift Interlock Switch: Testing and Inspection
Inspect that there is continuity between each terminal.
a. Shift Position: P position (Release button is not pushed):
Tester Connection: 3-1 (P1-P)
Specified Value: Continuity
b. Shift Position: P position (Release button is pushed):
Tester Connection: 3-1 (P1-P), 4-1 (P2-P)
Specified Value: Continuity
c. Shift Position: R, N, D, 2, L position:
Tester Connection: 4-1 (P2-P)
Specified Value: Continuity
If continuity is not as specified, replace the switch.