Alarm Horn Relay: Testing and Inspection

HORN RELAY CIRCUIT

CIRCUIT DESCRIPTION

When the theft deterrent system is activated, it causes the Tr in the ECU to switch ON and OFF in approximately 0.4 sec. cycles. This switches the horn
relay ON and OFF, thus the horns blow (See the wiring diagram).

In this condition, if any of the following operations is done, the Tr in the ECU goes OFF and the horn relay switches OFF, thus stopping the horns from
blowing:

1. Unlock the front LH or RH door with key.
2. Turn the ignition switch to ACC or ON position.
3. Unlock the doors with the wireless door lock control system.
4. Wait for approximately 60 seconds.

Horn Relay Circuit

WIRING DIAGRAM

Step 1

INSPECTION PROCEDURE

HINT:  The flow chart is based on the premise that horns blow normally whenever the horn switch is operated. If horn operation is not normal when the
horn switch is opened, check the horn switch.