Avalon XL V6-3.0L (1MZ-FE) (1997)
e. After connecting terminal 16 to terminal 17, connect 17 to terminal 2.
Then, check that the voltage rises from 0 volt to battery positive voltage within time as shown in illustration.
If operation is not as specified, replace the switch.
3. INSPECT WASHER LINKED OPERATION
a. Connect the positive (+) lead from the battery to terminal 17 and the negative (-) lead to terminal 2.
b. Connect the positive (+) lead from the voltmeter to terminal 7 and the negative (-) lead to terminal 2.
c. Push in the washer switch. Check that the voltage changes, as shown in the table.
If operation is not as specified, replace the switch.