toyota Workshop Repair Guides

Toyota Workshop Service and Repair Manuals

Coolant Temperature Sensor / Switch HVAC|Testing and Inspection|Page 2206 > < Radiator Cooling Fan Temperature Sensor / Switch|Specifications|Page 2201
Page 1
background image

Coolant Temperature Sensor / Switch HVAC: Testing and Inspection

1. INSPECT No.1 SWITCH CONTINUITY

a. Using an ohmmeter, check that there is no continuity between the terminals when the coolant temperature is above 98 °C (208 °F).

If there is continuity, replace the switch.

b. Using an ohmmeter, check that there is continuity between the terminals when the coolant temperature is below 88 °C (190 °F).

If there is no continuity, replace the switch.

2. INSPECT No.2 SWITCH CONTINUITY

a. Using an ohmmeter, check that there is no continuity between the terminal and switch body when the coolant temperature is above 93 °C (199 

°F).
If there is continuity, replace the switch.

b. Using an ohmmeter, check that there is continuity between the terminals when the coolant temperature is below 83 °C (181 °F).

If there is no continuity, replace the switch.

Coolant Temperature Sensor / Switch HVAC|Testing and Inspection|Page 2206 > < Radiator Cooling Fan Temperature Sensor / Switch|Specifications|Page 2201