Refrigerant Pressure Sensor / Switch: Service and Repair

REMOVAL

1. DISCHARGE REFRIGERANT FROM REFRIGERATION SYSTEM

HINT:  At the time of installation, please refer to the following item. 
Evacuate air from refrigeration system.
Charge system with refrigerant and inspect for leakage of refrigerant.

Specified amount: 850 ± 50 g (29.98 ± 1.76 oz.)

2. REMOVE PRESSURE SWITCH FROM LIQUID TUBE

Disconnect the connector and remove the pressure switch.
Torque: 10 N.m (100 kgf.cm, 7 ft.lbf) 

HINT:
^

Lock the switch mounted on the tube with an open end wrench, being careful not to deform the tube and remove the switch.

^

At the time of installation, please refer to the following item.
Lubricate a new O-ring with the compressor oil and install them to the switch.

INSTALLATION

Installation is in the reverse order of removal.