Avalon XLS V6-3.0L (1MZ-FE) (1998)
Variable Induction Control Solenoid: Component Tests and General Diagnostics
INSPECTION
1. REMOVE V-BANK COVER AND EMISSION CONTROL VALVE SET AND HIGH-TENSION CORD COVER
2. REMOVE VSV
(a) Disconnect the 2 vacuum hoses from the VSV.
(b) Remove the screw and VSV.
3. INSPECT VSV FOR OPEN CIRCUIT
Using an ohmmeter, check that there is continuity between each terminals.
Resistance: 33-39 Ohms at 20°C (68°F)
If there is no continuity, replace the VSV.
4. INSPECT VSV FOR GROUND
Using an ohmmeter, check that there is no continuity between each terminal and the body.
If there is continuity, replace the VSV.
5. INSPECT VSV OPERATION
(a) Check that air flows from port E to the filter.