(5) Turn the power switch on (IG).
(6) Turn on the intelligent tester.
(7) Reading the stroke sensor 1 value shown in the data list, slowly turn the brake pedal stroke sensor to the right and left to adjust the value to
the standard voltage.
Standard voltage:
0.8 to 1.2 V
(8) Fully tighten the 2 bolts.
Torque: 8.5 Nm (87 kgf-cm, 75in-lbf)
NOTICE: Do not depress the brake pedal after turning the power switch on (IG).
(9) Turn off the intelligent tester and turn the power switch off.
(10) Disconnect the intelligent tester from the DLC3.
2. INSTALL LOWER INSTRUMENT PANEL FINISH PANEL LH (for TMC Made) See: Body and Frame/Interior Moulding / Trim/Dashboard /
Instrument Panel/Service and Repair/Removal and Replacement/Instrument Panel Safety Pad (for TMC Made)(From 10-2006)/Installation
3. INSTALL LOWER INSTRUMENT PANEL FINISH PANEL LH (for TMMK Made) See: Body and Frame/Interior Moulding / Trim/Dashboard
/ Instrument Panel/Service and Repair/Removal and Replacement/Instrument Panel Safety Pad (for TMMK Made)(From 10-2006)/Installation
4. INSTALL COWL SIDE TRIM SUB-ASSEMBLY LH See: Body and Frame/Interior Moulding / Trim/Headliner/Service and Repair/Roof
Headlining/Installation
5. INSTALL FRONT DOOR SCUFF PLATE LH See: Body and Frame/Interior Moulding / Trim/Headliner/Service and Repair/Roof
Headlining/Installation
6. PREFORM LINEAR VALVE OFFSET LEARNING
HINT: Refer the procedures up to "ELECTRONICALLY CONTROLLED BRAKE SYSTEM". See: Antilock Brakes / Traction Control
Systems/Testing and Inspection/Programming and Relearning/Initialization
7. CHECK AND CLEAR DTC
HINT: Refer the procedures up to "ELECTRONICALLY CONTROLLED BRAKE SYSTEM". See: Antilock Brakes / Traction Control
Systems/Testing and Inspection/Reading and Clearing Diagnostic Trouble Codes/DTC Check / Clear
8. PERFORM INITIALIZATION
NOTICE: Some systems need initialization after reconnecting the cable to the negative battery terminal. See: Testing and
Inspection/Programming and Relearning/Repair Instruction - Initialization