(a) Disconnect the mass air flow meter connector (*1).
(b) Disconnect the purge VSV connector (*2).
(c) Disconnect the 2 purge VSV vacuum hoses (*3).
(d) Disconnect the purge line hose from the clamp (*4).

(e) Disconnect the No. 2 ventilation hose from the air cleaner hose.

(f) Lock the No. 1 air cleaner hose clamp, and then disconnect the No. 1 air cleaner hose from the throttle body.

(g) Remove the 2 bolts and air cleaner cap.
(h) Remove the air cleaner filter element from the air cleaner case.

4. REMOVE THROTTLE BODY

(a) Disconnect the throttle position sensor connector and wire harness clamp.