Starting System - Vehicle Start After Battery Depletion
ELECTRICAL
EL017-06
Title:
VEHICLE START AFTER
BATTERY DEPLETION
Models:
'05 - '07 Avalon & '07 Camry
December 22, 2006
Introduction
In vehicles equipped with the Smart Key system, the starting function may not be operational after recharging a discharged battery or jump starting the
vehicle. If battery voltage drops below 9V, the Steering Lock ECU may need to be re-initialized. Follow the initialization procedure below to re-initialize
the Steering Lock ECU.
Applicable Vehicles
^
2005 - 2007 model year Avalon vehicles.
^
2007 model year Camry vehicles.
Initialization
Procedure
1.
Confirm that the DCC fuse is installed.
NOTE:
If DCC fuse is NOT installed, install at this time.
2.
Place the shift lever in the "P" position.
3.
Open and close the driver's side door.
NOTE:
This will start an initialization process between the Steering Lock ECU and the Junction Block ECU.
4.
Depress the brake pedal.
5.
Press the engine "START STOP" switch.
6.
Re-initialize any affected power systems.
2005 model year Avalon:
^
Refer to TSB No. PD008-05, "Power System Initialization During PDS".
2006 model year Avalon:
^
Refer to TSB No. PD014-06, "Power System Initialization During PDS".
2007 model year Avalon:
^
Refer to TSB No. PD055-06, "Initialization of Sliding Roof During PDS".
^