A.

Using a digital voltmeter, measure the auxiliary battery voltage between the terminals to determine the charging time.

NOTE:

^

If measuring the voltage with the negative (-) terminal connected, push the power switch to select the "OFF" mode, turn OFF all electrical
systems, and wait 60 seconds or more. This removes the surface charge.

^

Prior to measuring the voltage, wait 20 minutes or more after the hybrid system stops. This removes the surface charge.

CAUTION:

^

Do NOT charge with the battery mounted in the vehicle.

^

Charge in a well-ventilated area.

^

Do NOT allow sparks or fire near the battery.

B.

Obtain the Automatic Battery Trickle Charger (SST P/N 00002-YA122-01*).

* Supercedes P/N 00002-YA121-01. P/N 00002-YA121-01 may still be used (with switch in 10 AMP position).

NOTE IF USING P/N 00002-YA121-01:

Ensure that the charge current switch is set on the 10 AMP position. When operated in the 10 AMP position, the Automatic Battery Trickle
Charger (SST P/N 00002-YA121-01) is designed to automatically regulate charging current and voltage. Using this mode, the charger will
minimize charge time, while preventing overheating and possible battery damage. Charging in the 2 AMP position is NOT recommended for
the Camry HV 12-volt battery, due to prolonged charge time.

CAUTION:

Use of standard battery chargers is NOT recommended on the Camry HV 12-volt battery, in order to prevent battery damage.

Electrical - HV & Auxiliary Battery Maintenance|Page 7731 > < Electrical - HV & Auxiliary Battery Maintenance|Page 7729