toyota Workshop Repair Guides

Toyota Workshop Service and Repair Manuals

Component Inspection|Page 1459 > < Variable Valve Timing Actuator|Description and Operation|Page 1456
Page 1
background image

Variable Valve Timing Actuator: Testing and Inspection
Component Inspection

INSPECT CAMSHAFT TIMING OIL CONTROL VALVE ASSEMBLY 

a. Measure the resistance between the terminals.

Standard: 6.9 to 7.9 Ohm at 20°C (68°F) 

If the result is not as specified, replace the OCV assembly.

b. Connect the battery's positive (+) lead to terminal 1 and negative (-) lead to terminal 2, and check the movement of the valve.

NOTE:  Confirm that the valve moves freely and does not become stuck in any position. If necessary, replace the OCV assembly.

HINT:  If the valve cannot return properly because of foreign matter, a small pressure leak in the advanced direction may occur and a DTC will be
output.

Component Inspection|Page 1459 > < Variable Valve Timing Actuator|Description and Operation|Page 1456