Positive Crankcase Ventilation Valve: Service and Repair

REPLACEMENT 

1. REMOVE VENTILATION VALVE SUB-ASSEMBLY

a. Disconnect the PCV hose from the PCV valve.
b. Remove the PCV valve.

2. INSTALL VENTILATION VALVE SUB-ASSEMBLY

a. Reinstall the PCV valve.

1. Apply adhesive to 2 or 3 threads.

Adhesive: Part No. 08833-00070, THREE BOND 1324 or equivalent

2. Reinstall the PCV valve.

Torque: 19 N.m (193 kgf.cm, 14 ft.lbf) 

b. Connect the PCV hose to the PCV valve.