Camry V6-3.3L (3MZ-FE) (2005)
Knock Sensor: Testing and Inspection
INSPECTION
INSPECT KNOCK SENSOR
Using an ohmmeter, measure the resistance between the terminals.
Standard: 120 to 280 kOhms at 20°C (68°F)
HINT: If the result is not as specified, replace the sensor.