Camry V6-3.3L (3MZ-FE) (2005)
Variable Valve Timing Actuator Position Sensor: Service and Repair
REPLACEMENT
HINT: A bolt without torque specification is a standard bolt
1. REMOVE AIR CLEANER INLET ASSEMBLY
2. REMOVE AIR CLEANER ASSEMBLY
3. REMOVE VVT SENSOR
a. Disconnect the sensor connector.
b. Remove the bolt and sensor.
4. INSTALL VVT SENSOR
a. Apply a light coat of engine oil to the O-ring on the sensor.
b. Install the sensor with the bolt.
Torque: 8.0 N.m (82 kgf.cm, 71 in.lbf)
c. Connect the sensor connector.
5. INSTALL AIR CLEANER ASSEMBLY
6. INSTALL AIR CLEANER INLET ASSEMBLY
7. CHECK CONNECTION OF VACUUM HOSE