36. CONNECT TRANSMISSION CONTROL CABLE ASSEMBLY
a. Connect the floor shift cable to the floor shift assembly.
HINT:
-
Install it with the uneven surface facing to up.
-
Ensure that the claws fit tightly.
37. CONNECT FLOOR SHIFT PARKING LOCK CABLE ASSEMBLY
a. Set the accessory tool.
(1) Shift the shift lever to P position and turn the ignition switch to the LOCK position. (TMC made)
(2) Shift the shift lever to N position and turn the ignition switch to the ACC. position (TMMK made)
(3) Set the accessory tool to the shift lock control unit assembly as shown in the illustration.
Accessory tool parts No.:
TMC Made: 33693-33010
TMMK Made: 33693-06010
HINT: Only in the case of reusing the shift lock control unit assembly.
b. Using a screwdriver, unlock the claw of the lock key of automatic adjustment part.