Camry V6-3.5L (2GR-FE) (2008)
(1) Remove the detection pump from the charcoal canister.
(2) Check that air flows from port A to B and then C.
If the result is not as specified, replace the charcoal canister assembly.
(3) Connect the positive (+) lead to terminal 7 and the negative (-) lead to terminal 6.
(4) Check that the valve is closed.
If the result is not as specified, replace the charcoal canister assembly.
(5) Install the detection pump.