toyota Workshop Repair Guides

Toyota Workshop Service and Repair Manuals

Radiator Cooling Fan Motor|Specifications|Page 1921 > < Radiator Cooling Fan Motor|Specifications|Page 1919
Page 2
background image

3. Inspect No.1 cooling fan.

a. Disconnect the cooling fan connector.
b. Connect battery and ammeter to the cooling fan connector.
c. Check that the cooling fan rotates smoothly, and check the reading on the ammeter.

Standard amperage: 8.3 - 11.3 A at 20°C (68°F) 

d. Reconnect the cooling fan connector.

4. Inspect No.2 cooling fan.

a. Disconnect the cooling fan connector.
b. Connect battery and ammeter to the cooling fan connector.
c. Check that the cooling fan rotates smoothly, and check the reading on the ammeter.

Standard amperage: 8.3 - 11.3 A at 20°C (68°F) 

d. Reconnect the cooling fan connector.

Radiator Cooling Fan Motor|Specifications|Page 1921 > < Radiator Cooling Fan Motor|Specifications|Page 1919