toyota Workshop Repair Guides

Toyota Workshop Service and Repair Manuals

Blower Motor > < Air Inlet Servomotor|Page 5650
Page 1
background image

Air Door Cable: Adjustments

AIR INLET DAMPER CONTROL CABLE

Air Inlet Damper Cable Adjustment

1.

Set air inlet damper and control lever to "FRESH" position.

2.

Install control cable and lock clamp.

AIR MIX DAMPER CONTROL CABLE

Air Mix Damper Cable Adjustment

1.

Set air mix damper and control switch to "COOL" position.

2.

Install control cable and lock clamp while lightly pushing outer cable in direction shown by arrow on image.