toyota Workshop Repair Guides

Toyota Workshop Service and Repair Manuals

Fuel Pressure Control Solenoid|Specifications|Page 3562 > < Fuel Pressure Control Solenoid|Specifications|Page 3560
Page 1
background image

Fuel Pressure Control Solenoid: Description and Operation

PURPOSE / OPERATION 

The ECM turns on the VSV (Vacuum Switching Valve) for fuel pressure control to draw the air into the diaphragm chamber of the fuel pressure
regulator if it detects that the temperature of the engine coolant is too high during engine starting.
The air drawn into the chamber increases the fuel pressure to prevent fuel vapor lock at high engine temperature in order to help the engine start
when it is warm.
Fuel pressure control ends approx. 120 sec. after the engine is started.

Fuel Pressure Control Solenoid|Specifications|Page 3562 > < Fuel Pressure Control Solenoid|Specifications|Page 3560