Using an ohmmeter, measure the resistance between terminals THA and E2.

-

If the resistance is not as specified, replace the MAF meter.

2. INSPECT MAF METER OPERATION

-

Connect the MAF meter connector.

-

Using a voltmeter, connect the positive (+) tester probe to terminal VG, and negative (-) tester probe to terminal VG-.

-

Blow air into the MAF meter, and check that the voltage fluctuates.

-

If operation is not as specified, replace the MAF meter.

-

Disconnect the MAF meter connector.