toyota Workshop Repair Guides

Toyota Workshop Service and Repair Manuals

Electrical Specifications|Page 5442 > < Electrical Specifications
Page 1
background image

Starter Motor: Mechanical Specifications

Spring Tension, Ounces ................................................................................................................................................................................................  62-84
No Load Test
Amperes .............................................................................................................................................................................................................................  90
Volts ................................................................................................................................................................................................................................  11.5
RPM ...............................................................................................................................................................................................................................  3000

[01] -- Reduction type starter, 1.4 kilowatt rating.

Electrical Specifications|Page 5442 > < Electrical Specifications