Camry LE Sedan L4-2164cc 2.2L DOHC (5S-FE) MFI (2000)
Generator: Service and Repair
Removal and Installation
REMOVAL
1. DISCONNECT CONNECTOR AND WIRE FROM GENERATOR
a. Disconnect the wire clamp from the wire clip on the rectifier end frame.
b. Disconnect the generator connector.
c. Remove the rubber cap and nut, and disconnect the generator wire.
2. REMOVE GENERATOR
a. Loosen the adjusting lock bolt (w/ A/C), adjusting bolt and pivot bolt.
Torque:
Pivot bolt: 52 Nm (530 kg.cm, 38 ft.lb)
Adjusting lock bolt (W/ A/C) or adjusting bolt (w/o A/C) 18 Nm (185 kg.cm, 13 ft.lb)
b. Remove the drive belt.
c. Remove the adjusting lock bolt (w/ A/C) or adjusting bolt (w/o A/C) and pivot bolt.
d. Remove the generator.
INSTALLATION
Installation is in the reverse order of removal