Camry LE Sedan V6-3.0L (1MZ-FE) (1998)
Ignition Cable: Testing and Inspection
HIGH-TENSION CORDS INSPECTION
(a) Remove the V-bank cover.
(b) Disconnect the high-tension cords from spark plugs.
(1) Using needle-nose pliers, disconnect the cord clamp from the engine wire protector.
(2) Disconnect the high-tension cords at the rubber boot. Do not pull on the cords.
NOTICE: Pulling on or bending the cords may damage the conductor inside.
(3) Disconnect the high-tension cords from the clamp.
(c) Disconnect the high-tension cords from the ignition coils.
(1) Using a screwdriver, lift up the lock claw and disconnect the holder from the ignition coils.
(2) Disconnect the high-tension cord at the grommet. DO NOT pull on the cord.
NOTICE:
-
Pulling on or bending the cords may damage the conductor inside.
-
Do not wipe any of the oil from the grommet after the high-tension cord is disconnected.