Camry LE Sedan V6-3.0L (1MZ-FE) (1998)
1.
Locate the vacuum hose going from charcoal canister to Port F of the Vapor Pressure Sensor VSV (see Figure 3).
2.
Remove vacuum hose from Port F of the Vapor Pressure Sensor VSV and connect a hand-held vacuum pump to Port F using a short length of
vacuum hose.
3.
Apply at least 10 mm Hg vacuum to the VSV.
Is a vacuum held for at least 1 minute?
YES --> Go to Step 4.
NO --> Replace the Vapor Pressure Sensor VSV.
4.
Disconnect the hand-held vacuum pump and reconnect the vacuum hose from the canister to the Vapor Pressure Sensor VSV.
5.
Locate the vacuum hose going from charcoal canister to Port P of the Vapor Pressure Sensor VSV (see Figure 4).