Throttle Valve Solenoid: Description and Operation

CIRCUIT DESCRIPTION 

The shift solenoid valve SLN controls the hydraulic pressure acting on the accumulator control valve when gears are shifted and performs smooth
gear shifting.
The ECM determines optimum operating pressure according to the signals from the throttle position sensor, vehicle speed sensor and direct clutch
speed sensor and controls the volume of current flow to the solenoid valve.
The amount of current to the solenoid is controlled by the (*) duty ratio of ECM output signals, causing a momentary change to the hydraulic
pressure acting on the clutches during gear shifting.
When the duty ratio is high, the hydraulic pressure acting on the clutches is low.

(*) Duty Ratio
The duty ratio is the ratio of the period of continuity in one cycle.
For example, if A is the period of continuity in one cycle and B is the period of non-continuity, then

 

Duty Ratio  = A/A+B X 100 (%)