toyota Workshop Repair Guides

Toyota Workshop Service and Repair Manuals

Condenser Fan > < Condenser HVAC|Locations|Page 4995
Page 5
background image

c. Install a O-ring to the cooler refrigerant discharge hose No.1.

d. Connect the cooler refrigerant discharge hose No.1 to the cooler condenser assy with the bolt.

Torque: 5.4 N.m (55 kgf.cm, 47 in.lbf) 

13. CHARGE REFRIGERANT 

SST 07110-58060 (07117-58060, 07117-58070, 07117-58080, 07117-58090, 07117-78050, 07117-88060, 07117-88070, 07117-88080)

Specified amount: 550 ± 50 g (19.37 ± 1.76 oz.) 

14. WARM UP ENGINE
15. INSPECT LEAKAGE OF REFRIGERANT 

Condenser Fan > < Condenser HVAC|Locations|Page 4995