toyota Workshop Repair Guides

Toyota Workshop Service and Repair Manuals

Exhaust Gas Recirculation > < Thermal Vacuum Valve - EVAP|Locations|Page 1745
Page 1
background image

Thermal Vacuum Valve - EVAP: Testing and Inspection

Evaporative TVV Test

1.

Drain coolant from radiator into a suitable container.

2.

Remove the TVV from the water by-pass outlet.

3.

Cool TVV to below 95°F (35°C) with cool water.

4.

Blow air into a port, ensure the valve is closed and does not pass air.

5.

Heat TVV to above 129°F (54°C) with hot water.

6.

Blow air into a port, ensure the valve is open and air passes freely through valve.

7.

Apply adhesive to threads of the TVV and reinstall.

Torque Value:

22 ft.lb (29 Nm)

8.

Refill cooling system and inspect for leaks.

Exhaust Gas Recirculation > < Thermal Vacuum Valve - EVAP|Locations|Page 1745