EGR Valve: Service and Repair

PROCEDURE

Removal

1. Disconnect Negative (-) Terminal Cable From Battery.

CAUTION:  Work must be started after 90 seconds from the time the ignition switch is turned to the LOCK position and the negative (-) terminal
cable is disconnected from the battery.

2. Remove No.2 Exhaust Gas Recirculation (EGR) pipe; remove the 4 nuts, EGR pipe and 2 gaskets.

3. Disconnect the EGR Gas Temperature Sensor connector and clamp.
4. Remove EGR Valve and Vacuum Modulator assembly.

^

Disconnect the following hoses:

Vacuum hose from port P of EGR Vacuum Modulator. (1)
Vacuum hose from port Q of EGR Vacuum Modulator. (2)
Vacuum hose from port R of EGR Vacuum Modulator. (3)
Vacuum hose from EGR Valve. (4)

EGR Valve|Specifications|Page 2703 > < EGR Valve|Specifications|Page 2701